Energy Performance Ratings
The following NFRC ratings are summaries for WeatherBarr products with grid. For the complete detailed NFRC ratings for each series click the PDF link next to the series name.
New Construction Windows
Replacement Windows

To be labeled as an ENERGY STAR product, the U-factor and SHGC (Solar Heat Gain Coefficient) ratings must be less than or equal to those established by ENERGY STAR. The following is the ENERGY STAR criteria established in 2010:

Cornerstone Series
Download a PDF of the complete detailed Cornerstone Series NFRC ratings here.
| | U-Value | SHGC | Condensation Resistance |  |
Single Hung
|
| Energy Smart I |
0.30 |
0.30 |
55 |
N, NC, SC |
| Energy Smart II |
0.29 |
0.30 |
59 |
N, NC, SC |
| Energy Smart III |
0.24 |
0.25 |
66 |
N, NC, SC, S |
| Solar Smart I |
0.30 |
0.22 |
55 |
N, NC, SC, S |
| Solar Smart II |
0.28 |
0.22 |
59 |
N, NC, SC, S |
| Solar Smart III |
0.23 |
0.19 |
67 |
N, NC, SC, S |
Double Hung
|
| Energy Smart I |
0.31 |
0.29 |
56 |
N, NC, SC |
| Energy Smart II |
0.29 |
0.29 |
60 |
N, NC, SC |
| Energy Smart III |
0.23 |
0.25 |
65 |
N, NC, SC, S |
| Solar Smart I |
0.30 |
0.22 |
55 |
N, NC, SC, S |
| Solar Smart II |
0.29 |
0.22 |
61 |
N, NC, SC, S |
| Solar Smart III |
0.23 |
0.19 |
65 |
N, NC, SC, S |
Horizontal Slider
|
| Energy Smart I |
0.30 |
0.30 |
55 |
N, NC, SC |
| Energy Smart II |
0.28 |
0.30 |
60 |
N, NC, SC |
| Energy Smart III |
0.22 |
0.26 |
67 |
N, NC, SC, S |
| Solar Smart I |
0.29 |
0.22 |
56 |
N, NC, SC, S |
| Solar Smart II |
0.28 |
0.22 |
60 |
N, NC, SC, S |
| Solar Smart III |
0.22 |
0.20 |
67 |
N, NC, SC, S |
Picture Window
|
| Energy Smart I |
0.28 |
0.31 |
58 |
N, NC, SC |
| Energy Smart II |
0.27 |
0.31 |
61 |
N, NC, SC |
| Energy Smart III |
0.21 |
0.27 |
67 |
N, NC, SC, S |
| Solar Smart I |
0.28 |
0.23 |
58 |
N, NC, SC, S |
| Solar Smart II |
0.27 |
0.23 |
61 |
N, NC, SC, S |
| Solar Smart III |
0.21 |
0.20 |
67 |
N, NC, SC, S |
270 Series
Download a PDF of the complete detailed 270 Series NFRC ratings here.
| | U-Value | SHGC | Condensation Resistance |  |
Single Hung
|
| Energy Smart I |
0.32 |
0.29 |
56 |
NC, SC |
| Energy Smart II |
0.31 |
0.29 |
59 |
NC, SC |
| Solar Smart I |
0.32 |
0.25 |
56 |
NC, SC, S |
| Solar Smart II |
0.30 |
0.25 |
59 |
N, NC, SC, S |
Single Slider
|
| Energy Smart I |
0.32 |
0.28 |
56 |
NC, SC |
| Energy Smart II |
0.30 |
0.28 |
59 |
N, NC, SC |
| Solar Smart I |
0.31 |
0.24 |
56 |
NC, SC, S |
| Solar Smart II |
0.3 |
0.24 |
59 |
N, NC, SC, S |
Picture Window
|
| Energy Smart I |
0.30 |
0.30 |
56 |
N, NC, SC |
| Energy Smart II |
0.30 |
0.30 |
59 |
N, NC, SC |
| Solar Smart I |
0.30 |
0.26 |
56 |
N, NC, SC, S |
| Solar Smart II |
0.29 |
0.26 |
59 |
N, NC, SC, S |
730 Series
Download a PDF of the complete detailed 730 Series NFRC ratings here.
| | U-Value | SHGC | Condensation Resistance |  |
Double Hung
|
| Energy Smart I |
0.31 |
0.28 |
56 |
NC, SC |
| Energy Smart II |
0.30 |
0.28 |
56 |
N, NC, SC |
| Energy Smart III |
0.24 |
0.24 |
65 |
N, NC, SC, S |
| Solar Smart I |
0.31 |
0.24 |
56 |
NC, SC, S |
| Solar Smart II |
0.29 |
0.24 |
59 |
N, NC, SC, S |
| Solar Smart III |
0.24 |
0.20 |
65 |
N, NC, SC, S |
Double Slider
|
| Energy Smart I |
0.30 |
0.27 |
56 |
N, NC, SC, S |
| Energy Smart II |
0.29 |
0.27 |
61 |
N, NC, SC, S |
| Energy Smart III |
0.23 |
0.24 |
67 |
N, NC, SC, S |
| Solar Smart I |
0.30 |
0.24 |
56 |
N, NC, SC, S |
| Solar Smart II |
0.29 |
0.24 |
61 |
N, NC, SC, S |
| Solar Smart III |
0.23 |
0.20 |
67 |
N, NC, SC, S |
Picture Window
|
| Energy Smart I |
0.27 |
0.32 |
59 |
N, NC, SC |
| Energy Smart II |
0.27 |
0.32 |
61 |
N, NC, SC |
| Energy Smart III |
0.22 |
0.28 |
68 |
N, NC, SC |
| Solar Smart I |
0.27 |
0.28 |
60 |
N, NC, SC |
| Solar Smart II |
0.26 |
0.28 |
62 |
N, NC, SC |
| Solar Smart III |
0.22 |
0.24 |
69 |
N, NC, SC, S |
4000 Series
Download a PDF of the complete detailed 4000 Series NFRC ratings here.
| | U-Value | SHGC | Condensation Resistance |  |
Casement
|
| Energy Smart I |
0.29 |
0.24 |
60 |
N, NC, SC, S |
| Energy Smart II |
0.28 |
0.24 |
63 |
N, NC, SC, S |
| Solar Smart I |
0.29 |
0.21 |
60 |
N, NC, SC, S |
| Solar Smart II |
0.28 |
0.21 |
63 |
N, NC, SC, S |
Awning
|
| Energy Smart I |
0.29 |
0.24 |
60 |
N, NC, SC, S |
| Energy Smart II |
0.28 |
0.24 |
63 |
N, NC, SC, S |
| Solar Smart I |
0.29 |
0.21 |
60 |
N, NC, SC, S |
| Solar Smart II |
0.28 |
0.21 |
63 |
N, NC, SC, S |
Picture Window
|
| Energy Smart I |
0.27 |
0.28 |
59 |
N, NC, SC |
| Energy Smart II |
0.26 |
0.28 |
61 |
N, NC, SC, S |
| Solar Smart I |
0.27 |
0.25 |
59 |
N, NC, SC, S |
| Solar Smart II |
0.26 |
0.25 |
62 |
N, NC, SC, S |
570 Series
Download a PDF of the complete detailed 570 Series NFRC ratings here.
| | U-Value | SHGC | Condensation Resistance |  |
Single Hung
|
| Energy Smart I |
0.32 |
0.29 |
56 |
NC, SC |
| Energy Smart II |
0.31 |
0.29 |
59 |
NC, SC |
| Solar Smart I |
0.32 |
0.25 |
56 |
NC, SC, S |
| Solar Smart II |
0.30 |
0.25 |
59 |
N, NC, SC, S |
Single Slider
|
| Energy Smart I |
0.32 |
0.28 |
56 |
NC, SC |
| Energy Smart II |
0.30 |
0.28 |
59 |
N, NC, SC |
| Solar Smart I |
0.31 |
0.24 |
56 |
NC, SC, S |
| Solar Smart II |
0.3 |
0.24 |
59 |
N, NC, SC, S |
Picture Window
|
| Energy Smart I |
0.30 |
0.30 |
56 |
N, NC, SC |
| Energy Smart II |
0.30 |
0.30 |
59 |
N, NC, SC |
| Solar Smart I |
0.30 |
0.26 |
56 |
N, NC, SC, S |
| Solar Smart II |
0.29 |
0.26 |
59 |
N, NC, SC, S |
Legacy Series
Download a PDF of the complete detailed LEGACY Series NFRC ratings here.
| | U-Value | SHGC | Condensation Resistance |  |
Double Hung
|
| Energy Smart I |
0.31 |
0.28 |
56 |
NC, SC |
| Energy Smart II |
0.30 |
0.28 |
56 |
N, NC, SC |
| Energy Smart III |
0.24 |
0.24 |
65 |
N, NC, SC, S |
| Solar Smart I |
0.31 |
0.24 |
56 |
NC, SC, S |
| Solar Smart II |
0.29 |
0.24 |
60 |
N, NC, SC, S |
| Solar Smart III |
0.24 |
0.20 |
65 |
N, NC, SC, S |
Double Slider
|
| Energy Smart I |
0.30 |
0.27 |
56 |
N, NC, SC, S |
| Energy Smart II |
0.29 |
0.27 |
60 |
N, NC, SC, S |
| Energy Smart III |
0.23 |
0.24 |
67 |
N, NC, SC, S |
| Solar Smart I |
0.30 |
0.24 |
57 |
N, NC, SC, S |
| Solar Smart II |
0.29 |
0.24 |
61 |
N, NC, SC, S |
| Solar Smart III |
0.23 |
0.20 |
67 |
N, NC, SC, S |
Picture Window
|
| Energy Smart I |
0.28 |
0.30 |
57 |
N, NC, SC |
| Energy Smart II |
0.27 |
0.30 |
59 |
N, NC, SC |
| Energy Smart III |
0.21 |
0.26 |
67 |
N, NC, SC, S |
| Solar Smart I |
0.27 |
0.26 |
57 |
N, NC, SC, S |
| Solar Smart II |
0.27 |
0.26 |
59 |
N, NC, SC, S |
| Solar Smart III |
0.20 |
0.22 |
68 |
N, NC, SC, S |
Restoration Series
Download a PDF of the complete detailed RESTORATION Series NFRC ratings here.
| | U-Value | SHGC | Condensation Resistance |  |
Double Hung
|
| Energy Smart I |
0.31 |
0.28 |
56 |
NC, SC |
| Energy Smart II |
0.30 |
0.28 |
60 |
N, NC, SC |
| Energy Smart III |
0.24 |
0.24 |
65 |
N, NC, SC, S |
| Solar Smart I |
0.31 |
0.24 |
56 |
NC, SC, S |
| Solar Smart II |
0.29 |
0.24 |
60 |
N, NC, SC, S |
| Solar Smart III |
0.24 |
0.20 |
65 |
N, NC, SC, S |
Double Slider
|
| Energy Smart I |
0.30 |
0.27 |
56 |
N, NC, SC, S |
| Energy Smart II |
0.29 |
0.27 |
60 |
N, NC, SC, S |
| Energy Smart III |
0.23 |
0.24 |
67 |
N, NC, SC, S |
| Solar Smart I |
0.30 |
0.24 |
57 |
N, NC, SC, S |
| Solar Smart II |
0.29 |
0.24 |
61 |
N, NC, SC, S |
| Solar Smart III |
0.23 |
0.20 |
67 |
N, NC, SC, S |
Picture Window
|
| Energy Smart I |
0.28 |
0.30 |
57 |
N, NC, SC |
| Energy Smart II |
0.27 |
0.30 |
59 |
N, NC, SC |
| Energy Smart III |
0.21 |
0.26 |
67 |
N, NC, SC, S |
| Solar Smart I |
0.27 |
0.26 |
57 |
N, NC, SC, S |
| Solar Smart II |
0.27 |
0.26 |
59 |
N, NC, SC, S |
| Solar Smart III |
0.20 |
0.22 |
68 |
N, NC, SC, S |
Restoration Advantage Series
Download a PDF of the complete detailed Restoration Advantage Series NFRC ratings here.
| | U-Value | SHGC | Condensation Resistance |  |
Double Hung
|
| Energy Smart I |
0.28 |
0.27 |
56 |
N, NC, SC, S |
| Energy Smart II |
0.27 |
0.27 |
60 |
N, NC, SC, S |
| Energy Smart III |
0.21 |
0.24 |
68 |
N, NC, SC, S |
| Solar Smart I |
0.28 |
0.23 |
56 |
N, NC, SC, S |
| Solar Smart II |
0.27 |
0.23 |
60 |
N, NC, SC, S |
| Solar Smart III |
0.21 |
0.20 |
68 |
N, NC, SC, S |
Double Slider
|
| Energy Smart I |
0.29 |
0.27 |
56 |
N, NC, SC, S |
| Energy Smart II |
0.27 |
0.27 |
61 |
N, NC, SC, S |
| Energy Smart III |
0.21 |
0.24 |
67 |
N, NC, SC, S |
| Solar Smart I |
0.28 |
0.24 |
56 |
N, NC, SC, S |
| Solar Smart II |
0.27 |
0.24 |
61 |
N, NC, SC, S |
| Solar Smart III |
0.21 |
0.24 |
67 |
N, NC, SC, S |
Picture Window
|
| Energy Smart III |
0.19 |
0.26 |
69 |
N, NC, SC, S |
| Solar Smart III |
0.19 |
0.22 |
69 |
N, NC, SC, S |
5000 Series
Download a PDF of the complete detailed 5000 Series NFRC ratings here.
| | U-Value | SHGC | Condensation Resistance |  |
Casement
|
| Energy Smart I |
0.29 |
0.24 |
60 |
N, NC, SC, S |
| Energy Smart II |
0.28 |
0.24 |
63 |
N, NC, SC, S |
| Solar Smart I |
0.29 |
0.21 |
60 |
N, NC, SC, S |
| Solar Smart II |
0.28 |
0.21 |
63 |
N, NC, SC, S |
Awning
|
| Energy Smart I |
0.29 |
0.24 |
60 |
N, NC, SC, S |
| Energy Smart II |
0.28 |
0.24 |
63 |
N, NC, SC, S |
| Solar Smart I |
0.29 |
0.21 |
60 |
N, NC, SC, S |
| Solar Smart II |
0.28 |
0.21 |
63 |
N, NC, SC, S |
Picture Window
|
| Energy Smart I |
0.28 |
0.28 |
59 |
N, NC, SC, S |
| Energy Smart II |
0.28 |
0.28 |
61 |
N, NC, SC, S |
| Solar Smart I |
0.28 |
0.25 |
59 |
N, NC, SC, S |
| Solar Smart II |
0.27 |
0.22 |
61 |
N, NC, SC, S |